TLI80
Application
- LED inset light, low protrusion 6,35 mm, sutaible for Runway (APP, ASR, END, THR, THREND, THRWB)
 
Files for download
TLI80-EN.pdfApplication
- APP - approach centre line and crossbar light
 - ASR - approach side row light
 - END - runway end light
 - THR - treshold light
 - THREND - threshold and runway end light
 - THRWB - threshold and wing bar light
 
Classification
- FAA AC 150/5345-46; Class 2, Mode 1*, Style 3
 - IEC TS 61827: Style 3, Size 3
 
       *does not apply to 2,2 A powered lights
Accordance with
- Engineering Brief No. 67D
 - IEC TS 61827
 - ICAO Annex 14, Vol. I
 - Figure: A1-1b, A2-1, A2-2, A2-3, A2-4, A2-8
 - EASA CS-ADR-DSN
 - Figure: U-1B, U-5, U-6, U-7, U-8, U-12
 - TP-312
 - Figure: A-1(b), B-1, B-2, B-3, B-4, B-B
 
Properties
- designed for simplicity and serviceability
 - light diameter size 12'' (304 mm)
 - easy winter mauntenece of the aerodrome thanks to 6,35 mm protrusion
 - light depth in base 68 mm
 - simple aluminium construction with stainless steel fasteners with a watertight IP68
 - no negative slope before prisms
 - non-glued, easily replaceble prisms
 - velve for watertightness test
 - only one type of prims for all light series TLI50, TLI80 and TLI81
 - optical parts made of borosilicate glass
 - operation with any CCR designed in accordance with IEC or FAA requirements
 - excellent efficiency and colour characteristics due to the use of LED technology
 - light output is variable as for halogen lamps, according to the requirements of Engieneering Brief No. 67D
 - lifetime of least 110 000 h of operation
 - efficient maintenance thanks to the common parts of the TLI50, TLI80, TLI81 series
 - additional heating possible with ARC (arctit kit), according to the requirements of Engieneering Brief No. 67D
 - monitoring function with function to disconect the light from the transformer (series loop) when LED failure is detected, according to the requrements of Engieneering Brief No. 67D
 
Resisted to
- temperature -55/+55 °C and thermal shock
 - humidity, snow, ice and water, watertight IP68
 - salt and UV radiation
 - static and shear load, recurrent mechanical and hydraulic impact according to the iec ts 61827
 - vibration 20/2 000 Hz with acceleration 10/15 G
 - shock wave 10 kV on 5 kA, according to the requirements of Engieneering Brief No. 67D
 - EMC ccording to the requirements of IEC 6100-6-2 and IEC 61000-6-4
 
Power source
- power cable with termination FAA AC 150/5345-26, L-823, Type II, Class A, Style 6
 - isolation transformer 6,6 A or 2,2 A at the output from the secondary line (power of the isolating transformer according to the power input of the light)
 
Mounting
- bases for light, size 12'' (002 560, 002 561, 002 566, 002 567)
 
Mechanical parameters
- weight (of one pack) ± 7,4 kg
 - dimensions (of one pack) 320x320x115 mm
 
 
	
						
						
						