Application
● a basic part of the descent lighting system for PAPI/APAPI airports and heliportsFiles for download
Classification
- FAA AC 150/5345; Style B, Class II
Accordance with
- Engineering Brief No. 67D
- IECTS 61827
- ICAO Annex 14, Vol. 1, Figure: A1-1B, U-26
- TP-312, Figure A-1 (b), B-19
Description/properties
- designed for simplicity and serviceability
- the light consists of two or tree projector units
- simple and durable aluminium construction with stainless steel fixings and IP54 protection rating
- easy maintenance thanks to removable projector units from the base plate in seconds
- base plate (for projector units) consisting of an anodised aluminium workpiece
- front lens made of glass
- operation with any CCR designed in accordance with IEC or FAA requirements
- exellent efficiency and colour characteristics thanks to the use of LED technology
- the power input is variable like halogen lamps, according to the requirements of Engineering Brief No. 67D
- heated front lens prevents icing on the optical system
- LED failure detection, as required by Engineering Brief No. 67D
- MONITORING with the function of disconnecting the light/projector unit from the transformer
- interchngeable with halogen PAPI/APAPI TP90 without changing the base plate
- fixed or mobile fixing option
Technical parameters
- unit weight approx. 15 kg
- dimensions of fixed mounting kits, (two projector units 56x80X75 cm, three projector units 56x80x90 cm)
Construction
- projector unit
- elements of vertical direction of the radiation (continuously 0°to 10°)
- base plate
- elements of the horizontal direction of the radiation (continuously+-1°)
- stakes/tubes
- breakable couplings
Resistance to
- temperature -55°C÷55°C temperature shock
- moisture, snow, water IP54
- salt fog, solar radiation and UV radiation
- wind resistance 480 km/h
- 10 kV (15kV) surge protection
- EMC as required by IEC TS 61827
Soure of light
- power cable with FAA AC5345-26, L-823 Type II, Clas A, Style 1
- isolation transformer 6.6 A or 2.2 A at the output secondary line (isolating transformer power 65 W-150 W)
Ordering codes
- lights with two proector units, fixed mounting
- lights with three projector units, fixed mounting
- TLP90-PAPI-S6 6.6 A airport serial power supply
- accessories
- TP90.CM clinometr
* mobile variants of TLP90 lights must be consulted